For the three-piece helical pile connector, cyclic models were proposed to capture its seismic performance. These models are tailored to the specific connectors tested, and their applicability should be verified for other types of helical pile connectors. It’s crucial to ensure the models are valid for different connectors before applying them to various seismic performance evaluations.

Typical Helical Pile Connector

Model for the Vertical Cyclic Behaviour of Helical Pile Connectors

Model for the Lateral Cyclic Behaviour of Helical Pile Connectors
For more information, please refer to:
El Naggar M.H., Youssef M.A., Ahmed M., 2007, “Monotonic and Cyclic Lateral Behaviour of Helical Pile Specialized Connectors”, Engineering Structures, 29(10): 2635-2640.
Youssef M.A., EL Naggar M.H., Ahmed M., 2006, “Monotonic and Cyclic Load Behaviour of Helical Pile Connectors in the Vertical Direction“, Canadian Journal of Civil Engineering, 33(1): 10-18.
DISCLAIMER
Simplex Engineering Inc. is not liable for any actual designs based on information from this site. Design engineers are responsible for complying with professional engineering regulations and adhering to applicable design standards, codes, and practices. We welcome the opportunity to collaborate on structural engineering projects. Don’t hesitate to contact us for more information about our services and fees.